ZPL Commands
^BM
76
45541L-004 Rev. A ZPL II Programming Guide 9/15/06
^BM
MSI Bar Code
Description The ^BM command is a pulse-width modulated, continuous, non-self- checking
symbology. It is a variant of the Plessey bar code (
^BP).
Each character in the MSI bar code is composed of eight elements: four bars and four adjacent
spaces.
^BM supports a print ratio of 2.0:1 to 3.0:1.
For the bar code to be valid, field data (
^FD) is limited to 1 to 14 digits when
parameter
e is B, C, or D. ^FD is limited to 1 to 13 digits when parameter e is A, plus
a quiet zone.
Format ^BMo,e,h,f,g,e2
This table identifies the parameters for this format:
Important • If additional information about the MSI bar code is required, go to
www.aimglobal.org.
Parameters Details
o = orientation Accepted Values:
N = normal
R = rotated 90 degrees (clockwise)
I = inverted 180 degrees
B = read from bottom up, 270 degrees
Default Value: current
^FW value
e = check digit
selection
Accepted Values:
A = no check digits
B = 1 Mod 10
C = 2 Mod 10
D = 1 Mod 11 and 1 Mod 10
Default Value: B
h = bar code height
(in dots)
Accepted Values: 1 to 32000
Default Value: value set by ^BY
f
= print
interpretation
line
Accepted Values:
N = no
Y = yes
Default Value: Y