Preventive and Corrective Maintenance
Hanger Assembly
224
13291L-001 Rev. A S4M Maintenance Manual 10/27/05
Remove the Main Logic Board
1.
Connect yourself to an antistatic device.
2. See RRP No. 1 on page 122 and remove the electronics cover.
3. Open the media door and remove the media and ribbon
4. See Figure 111. On the electronics side, disconnect all cables from the main logic board.
Figure 111 • Disconnect the Main Logic Board Connections
Caution • Observe proper electrostatic safety precautions when handling
static-sensitive components such as circuit boards and printheads.
Note • Take note of the orientation of all cables on the main logic board.
1
Printhead data (J3)
7
Transmissive sensor (P9)
2
Power-in (J8)
8
Reflective sensor (P7)
3
Front panel (J2)
9
Take-label sensor (J19)
4
Stepper motor (J9)
10
Communication expansion port
(J17)
5
Booster board (J7)
11
USB port (J14)
6
Ribbon sensor/head open (P4)
12
Serial port (J10)
F6
L
F
1A
1
2
3
4
5
6
7
8
10
11
12
9
Seitenansicht 247