Zebra 170PAX2 Series Bedienungsanleitung Seite 10

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 20
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 9
RTC ZPL II Commands
RTC General Information
6
47867L-001 Rev. A 05/25/2005
Example
This command string will cause 489 KBYTES to be set aside as Font Memory and make it
unavailable as label format memory. The memory remaining will only allow two labels to be
formatted at one time, and the time and date will be more precise for those two labels.
4. Substitute the values for B
through D from the previous
page into the following formula:
The “label queue” memory
required (in BYTES)
(B x C x D)/8 =
(E)
5. Substitute the values for A and E
into the following formula:
The
^CO command memory
required (in KBYTES)
(A-E)/1024)-5=
(F)
Note • If the value of (F) is less than zero, then no ^CO command is needed. If the value of
(F) is greater than zero, use the integer portion in the ^CO command.
Available RAM (A) = 71478 BYTES
Print Width (B) = 832 DOTS
Label Length (C) = 1000 DOTS
Max Labels Queued (D) = 2
Then —
The label queue memory required (E) =
(B x C x D)/8 = 208000 BYTES
And —
The ^CO command memory required (F) =
(71478-208000)/1024)-5=489.87 KBYTES
Therefore, the correct ^CO command string to add to
the label format would be:
^XA^COY,489^XZ
Note • For the Time 170PA X 2 print engine, you must disable the Reprint Function for the
Now Mode to function properly.
Seitenansicht 9
1 2 ... 5 6 7 8 9 10 11 12 13 14 15 ... 19 20

Kommentare zu diesen Handbüchern

Keine Kommentare