RTC ZPL II Commands
^SO
10
47867L-001 Rev. A 05/25/2005
^SO
Set Offset
Description The ^SO command is used to set the secondary and the third offset from the
primary Real-time Clock.
Format
^SOa,b,c,d,e,f,g
This table identifies the parameters for this format:
Parameters Details
a = clock set
Accepted Values:
2 (secondary) or 3 (third)
Default Value: value must be specified
b = months offset
Accepted Values:
–32000 to 32000
Default Value: 0
c = days offset
Accepted Values:
–32000 to 32000
Default Value: 0
d = years offset
1
Accepted Values: –32000 to 32000
Default Value: 0
e = hours offset
Accepted Values:
–32000 to 32000
Default Value: 0
f = minutes offset
Accepted Values:
–32000 to 32000
Default Value: 0
g = seconds offset
Accepted Values:
–32000 to 32000
Default Value: 0
1. Supports up to the year 2097.