Programming
Software command syntax
10/22/2008 TTP2100 Technical Manual P1003640-001
Results in an 6-byte response representing the serial number.
Results in a 1-byte response representing the control board revision. A minus sign indicates
that no revision has been made, while A indicates the first revision, and so on.
Results in a 1-byte response representing the temperature of the Printhead.
The answer is an signed byte (two's complement). If bit7 is 1 than it’s a negative value, invert
all bits and add 1 the get the value.
ESC ENQ 009
Serial-Number Enquiry
1B 05 09 hex
27 5 9 decimal
Example •
Send ESC ENQ 09d
Read 00h 00h 02h 2Bh C6h 28h (hex), or 000 000 002 043 198 040 (dec)
ESC ENQ 010
Control Board Revision Enquiry
1B 05 0A hex
27 5 10 decimal
Example •
Send ESC ENQ 10d
Read n
Where n can be ‘A’ (ASCII) or41h (hex) or 065 (dec)
ESC ENQ 011
Head Temperature Enquiry
1B 05 0B hex
27 5 11 decimal
Example •
Send ESC ENQ 11d
Read n
Where n is a value representing the approximate temperature in Celsius.