Programming
Software command syntax
10/22/2008 TTP2100 Technical Manual P1003640-001
Extended status is status from the printer together with devices connected to the I
2
C options-
bus available in some Zebra printers (the TTP 2100 series does not have any I
2
C bus so these
parts of the command are superfluous). The short message protocol gives replies up to 255
bytes. Other protocols may be defined in the future. Protocols are described in separate
documents.
ESC ENQ E results in a variable length reply:
Short message status examples
Example 1 • Out of paper presenter Jam, and shutter open error.
Example 2 • No errors in any device.
ESC ENQ E
Read Extended Status
1B 05 45 hex
27 5 69 decimal
n1 Protocol version, 11h = Short Message Protocol
n2 Protocol length in bytes
n3-n255 Data specified by the protocol
11 07 01 05 20 83 87 21 81 Hex

Status code 1 (shutter device)
Device Shutter
Status code 7 (printer device)
Status code 3 (printer device)
Device local host (printer)
Tag message length (bytes)
Tag ID: Status messages
Protocol Length in bytes
Protocol SM, version 1 (short message)
11 02 01 00 Hex 

Tag message length (bytes)
Tag ID: Status messages
Protocol Length in bytes
Protocol SM, version 1 (short message)