7 - 2 MP6000 BAR CODE PROGRAMMING GUIDE
Auxiliary Scanner Parameters
Auxiliary Scanner Decode with Unknown Type
If an auxiliary scanner is connected via SSI over RS-232 for Zebra scanners, HID Keyboard for non-Zebra
scanners, or standard RS-232, and the Send Raw Decode Data option is enabled, the MP6000 transmits
decode data with the code type set by this parameter. The default is value 1 (Send Unknown as Code 39).
Options:
•
*Send Unknown as Code 39
•
Send Unknown as Code 128
•
Send Unknown as PDF-417
•
Send Unknown as Data Matrix.
*Send Unknown as Code 39
(01h)