Zebra MP6000 Technical Information Seite 77

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 964
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 76
USB INTERFACE BAR CODES 1 - 59
3-byte Scale Status - Extended Scale Status Enabled: When enabled, the MP6200 scanner/scale sends
an additional scale status byte to the IBM POS with the information shown in Table 1-4.
*2-byte IBM USB Scale Status - Extended Scale Status Disabled
(0)
Table 1-4
Scale Status Byte 2
Bit Position Description
0 Configuration successful.
1 Scale under zero.
2 Scale over capacity.
3 Scale center-of-zero.
4 Scale requires zeroing.
5 Scale warm up in progress.
6 Duplicate weight (United Kingdom mode only).
7 Not defined (always 0).
NOTE Some IBM POS applications require a 3-byte extended scale status for better price/weight transaction
performance.
Seitenansicht 76
1 2 ... 72 73 74 75 76 77 78 79 80 81 82 ... 963 964

Kommentare zu diesen Handbüchern

Keine Kommentare