Troubleshooting
Printer Diagnostics
13163L Rev. 3 5/20/2004 Z4Mplus/Z6Mplus User Guide 99
FEED and PAUSE Self Test
Performing this self test temporarily resets the printer configuration to the factory default
values. These values are active only until power is turned off unless you save them
permanently in memory.
To perform a FEED and PAUSE self test, complete these steps:
1. Turn Off (O) the printer.
2. Press and hold FEED and PAUSE while turning the power On (I). Hold FEED and
PAUSE until the DATA light turns off.
No labels print at the end of this test.
Communication Diagnostics Test
This test is controlled from the front panel display (see Setting Communication Diagnostics
Mode on page 66). A typical printout from this test is shown in Figure 43. Turn the printer Off
(
O) to exit this self test.
Figure 43 • Communication Diagnostics Test Printout
Note • This label prints upside-down.