3. Lift the Upper Media Sensor assembly and
move the sensor and the wire cover to the
outside half. Carefully pull the wires through
the tie wrap. You may need to set aside the
sensor wire cover if the adjustment is far to the
outside.
4. Replace and tighten the Phillips head screw.
5. Make sure the wires are routed back into the
groove of the media sensor bracket.
Lower Media Sensor Adjustment
1. Locate the Lower Media Sensor Assembly
(Figure 13-A) under the rear idler roller. (It is a
spring clip holding a circuit board.)
2. Slide the sensor until the two brass-colored
infrared emitters are under the Upper Media
Sensor. Gently pull wires out as needed (wires
should have a little slack).
Note: If the sensor is being moved inward and a
large loop of wire develops, remove the
cover from the electronics side of the
printer and gently pull the wires through.
Clamp the wires so that they do not rub
any drive belts.
90 English
A
Figure 13
E:\jobs\EH91 Zebra\XiIII\XiIII-gb.vp
Wednesday, December 15, 1999 8:59:13 AM
Color profile: Disabled
Composite Default screen