ManualCalibration
Amanualcalibrationshouldbeperformedwheneveryouareusing
pre-printedlabels(orlabelbacking)oriftheprinterwillnotcorrectlyauto
calibrate.
1. Turnontheprinterpower.
2. Removeapproximately6”(152mm)oflabelsfromasectionof
backingmaterial.Loadthemediasothatonlythebackingmaterialis
threadedthroughtheprinterandundertheprinthead.
3. UsetheMediaTracking(^MN)commandtoselecttheappropriate
mediatype(refertotheZPLIIProgrammingGuide).
4. PressandholdthefeedbuttonuntilthegreenstatusLEDflashesonce,
thentwice.Releasethefeedbutton.
5. Theprinterwillsetthemediasensorforthelabelbackingbeingused.
Afteritisdonemakingthisadjustment,therollwillautomaticallyfeed
untilalabelispositionedattheprinthead.
6. Aprofileofthemediasensorsettings(similartotheexamplein
Figure32)willprint.Uponcompletion,theprinterwillsavethenew
settingsinmemoryandtheprinterisreadyfornormaloperation.
7. Pressthefeedbutton.Oneentireblanklabelshouldfeed.Ifthisdoes
nothappen,trydefaulting(refertothefour-flashsequencein“Feed
ButtonModes”onpage37)andrecalibratingtheprinter.
NOTE: Performingamanualcalibrationdisablestheauto
calibrationfunction.Toreturntoautocalibration,defaultthe
printer(seethefour-flashsequencein“FeedButtonModes”on
page37).