Applicator Interface Board Reconfiguration
Changing Jumper Settings for Isolated Mode
154
P1051584-002 8/23/12
17. Align the mounting holes in the applicator interface board with the holes in the back plane
of the print engine.
18. Reinstall the two mounting screws (1) to secure the applicator interface board (2) to the
back plane of the print engine.
Close the Electronics Enclosure
19. Ensure that all wires are routed properly and are not causing any obstructions, and then
carefully swing the electronics enclosure closed.
20. Slide the electronics cover onto the print engine.
21. Reinstall the four electronics cover mounting screws.