Seitenansicht 57
ZPL Basics
The ZPL Command
52
P1026208-001 Rev. B Software Integrator Guide 10/29/2010
If the default value for a command parameter suits your application, you need not specify
that parameter. However, parameters are “position-specific.” If you want to change just the
third parameter, for example, you must indicate that it is the third parameter that you want
to change. To do so, use a comma, the ZPL delimiter character, to mark each parameter’s
place (i.e. ^AA,,60). If you enter a parameter and all further parameters to the right are to
be defaulted, then no further commas are required.
Many commands are able to used global default and parameter settings. Common global
parameter settings are field orientation, font selection, font encoding method (^CI), bar
code (height, X-width and narrow to wide ratio), etc. to list some examples.
Figure 5-2 • ZPL Command Parameter Use Variations
Figure 5-3 • ZPL Command Parameter Examples
Table 5-2 • ZPL Command Parameter Examples
Number Description
1 Sets Global Parameters
- ^ BY (Bar Code Field Default.
3rd parameter is the default height for Code 39 (
^B3) bar code’s 3rd
parameter.
Note: The default values for were
^BY2,3.0,10 until changed here.
2
^B3 command string with 3rd parameter missing. ^BY Global parameter
used.
3
^B3 command string changed to non-defaults in the 4th and 5th parameters.
4
^B3 command string has no parameters specified. Uses defaults.
Note:
^B3 does not inherit any parameter values from the last ^B3 bar code.
^B3o,e,h,f,g Code 39 Bar Code and parameters.
^B3N,Y,80,N,N Actual command, all parameters used.
^B3,,80,N Actual command, the missing first, second,
and fifth parameters will use default
or global parameters. The parameter
delimiter (the comma) is missing after the
fourth parameter as well.
^XA
^BY4,2,100
^FT40,100
^B3N,N,,Y,N
^FD123456789^FS
^FT40,300
^B3N,N,,N,Y
^FD123456789^FS
^FT40,500
^B3
^FD123456789^FS
^XZ
ZPL II CODE GENERATED LABEL