Seitenansicht 81
Printer Power Requirements
KR403 Power Requirements
72
P1016701-001 KR403 Integrators Guide 12/23/2009
KR403 Power Requirements
The KR403 printer has some unique power requirements to operate efficiently, safely and
within safety and compliance regulation guidelines. To get the best performance, one should
use an approved power supply to operate the KR403 printer. See the price list for an approved
power supply.
If a non-Zebra supplied power supply is used with the KR403, it must comply with the
following requirements.
POWER SUPPLY OUTPUT CHARACTERISTICS
OUTPUT RA TIN G: 24.0 Volts, 2.92 Amps, +5 to +40 degrees C.
VOLTAGE: 24.0Vdc +5/-2% (Initial Tolerance, No Load)
CURREN T: 2.92A Maximum
OUTPUT REQUIREMENT WHEN PRINTING (worst case conditions)
M A X AV E RA G E PO W ER : 24.0V x 2.92A = 70 Watts typical
PEAK POWER (90VACin, 47Hz): 243W
OUTPU T REGULATION:
LINE REGULATI ON: ± 0 .5% over AC input opera ti ng range.
RIPPLE & NOISE: 240mV
PP
at Iou t = 2.9 2 Amps, Resistive Load
(4.7µF/50V ceramic Cap. On output, 20MHz BW)
TR ANSI ENT LOAD R ESPON SE: < 5mS Recovery, 40 % to 80% Lo ad Change .
OVERSHOOT, POWER-UP: 10% Max. at power-on or pow er-off.
HOLDUP TIME: 20ms Mini mu m, Ra te d DC Lo ad, 120 VAC /60 Hz.
OVER-VOLTAGE: Output Limited to +28V Ma x.
FU SE: Yes
TH ERMAL: Allowed, Not re qu ired
Remark:
When Short Circuit Protection or Over Current Protection is acti vated, the power supply wi ll shutdown autom atically. Once
the abnormal condition resulting in the fai lure being removed, the power supply will restart accordingly.
Automatic Recovery:
Over Voltage Protection is activated, the pow er supply will shutdown. The power suppl y is fully protected agai nst short circuits
and automatically recovers upon removal of the short without the need for re-cycling the AC input voltage.