Mobile Printing Systems
CPCL Programming Manual
Section 14
Configuration/
Control
Commands
pg. 14-74
continued
power.inactivity_timeout
type: getvar; setvar
This parameter refers to the inactivity timeout.
getvar result Current inactivity timeout in seconds.
Example
Description Instructs the printer to respond with the inactivity timeout value
Syntax ! U1 getvar “power.inactivity_timeout
Result “120 Seconds
setvar choices
“0” through “8190. Values are specified in seconds. A value of “0” disables
inactivity timeout.
Default “120
Example
Description Set inactivity timeout to 120 seconds
Syntax ! U1 setvar “power.inactivity_timeout” “120
Result Printer inactivity timeout will be set to 120 seconds