Zebra CPCL Spezifikationen Seite 380

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 497
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 379
Mobile Printing Systems
CPCL Programming Manual
Section 14
Configuration/
Control
Commands
pg. 14-154
continued
wlan.roam.max_chan_scan_time
type: getvar; setvar
This parameter sets how long the radio waits on a channel looking for probe responses.
getvar result Time radio waits on a channel looking for probe responses
Example
Description Gets current setting for how long radio waits on a channel
looking for probe responses
Syntax ! U1 getvar “wlan.roam.max_chan_scan_time”
Result “100
setvar choices
Values: 10 to 500
Default “100”
Example
Description Sets how long the radio waits on a channel looking for probe
responses.
Syntax ! U1 setvar “wlan.roam.max_chan_scan_time” “100
Seitenansicht 379
1 2 ... 375 376 377 378 379 380 381 382 383 384 385 ... 496 497

Kommentare zu diesen Handbüchern

Keine Kommentare