Mobile Printing Systems
CPCL Programming Manual
Section 14
Configuration/
Control
Commands
pg. 14-194
continued
rd.tag.calibrate
Type: setvar
This command sets the RFID programming position through a tag calibration or it restores the
programming position back to the printer default. Before running this command load the printer with RFID
media and close the printhead.
setvar choices
“restore, “run
Default N/A
Example 1
Description
This will restore the program position to the printer’s
default program position (label length - 1mm)
Syntax ! U1 setvar “rfid.tag.calibrate” “restore
Result Program position is set to a label length - 1 mm
Example 2
Description
This will perform a RFID tag calibration then set the
program position to the optimal position
Syntax ! U1 setvar “rfid.tag.calibrate” “run”
Result Program position is set to the optimal position
rd.tag.data
Type: getvar
This command will retrieve data from the RFID tag that is currently above the transponder.
getvar result The current tag’s data (Example 1) or “NO DATA” (Example 2).
Example 1
Description
This will return the current tag’s data. (In this example a tag is
present and its data is “0123456789ABCDEF12345678)
Syntax ! U1 getvar “rfid.tag.data
Result “01234567890ABCDEF12345678
Example 2
Description This message will return when no tag is present
Syntax ! U1 getvar “rfid.tag.data
Result “NO DATA