pg. 14-104
continued
ip.mirror.password
type: getvar, setvar
This parameter specifies the user password on the mirroring server assigned for mirroring updates
(fetch).
getvar result For security purposes the printer does not return password information
Example
Description This parameter retrieves the user password the printer is
currently using for mirroring updates (fetch).
Syntax ! U1 getvar “ip.mirror.password
Result “*”
setvar choices
alphanumeric text string (1 to 20 characters)
Default “password
Example
Description This parameter instructs the printer to use a specific password for
mirroring updates (fetch).
Syntax ! U1 setvar “ip.mirror.password” “password”
Result