SITE PREPARATION AND INSTALLATION 3 - 33
To ensure smooth scanning, ensure the platter is in place, take a steel can (e.g., a soup can), turn
it over so the harsher seam is facing down, and slide the can over the platter in the standard
scanning direction. The can must not catch on the checkstand, or the platter when swept across all
sections of the platter, in the correct direction.
For the long MP6000, secure the screws in place with lock nuts.
ii. Medium MP6000 and short (shelf mount) MP6000: If the platter is not flush, or the MP6000 rocks,
adjust the optional leveling screws to place the device at the correct height. This can be done from
the top of the MP6000, with the tower bezel removed and the tower cover slightly pushed back.
Figure 3-42
Adjusting Leveling Screws
When the platter is flush, its leading edge should be slightly below the checkstand, and the trailing
edge should be slightly above the checkstand.
Leveling Screw Holes
Under Platter
Leveling Screw
Holes Under Bezel
Medium UnitShort Unit
Leveling Screw Holes
Under Bezel
Leveling Screw Holes
Under Bezel
Leveling Screw
Holes Under Platter
Leveling Screw
Holes Under Platter
IMPORTANT Leveling screws are an optional accessory for medium size models (15.7 in./39.8 cm) and short size
models (13.9 in./35.3 cm) and can be ordered separately. Accessory kit MX301-SR00004ZZWR
contains four standard-length screws, and accessory kit MX302-SR00004ZZWR contains four
extra-length screws which will protrude 1"-inch (25 mm) below the bottom of the unit. See Figure 1-5
on page 1-11 for the installation location of these screws and for the locations of access holes for
turning the screws from above.