4 - 6 MP6000 INTEGRATOR GUIDE
a. Place 25 lb weights on the scanner as shown in Figure 4-2; three 5 lb weights centered on the center
of the scale, and two 5 lb weights centered on top.
Figure 4-2
Weight Calibration Configuration for Pounds
b. Place 11 kg weights on the scanner as shown in Figure 4-3; two 5 kg weights centered on the center of
the scale, and one 1 kg weight on top between the two 5 kg weights.
Figure 4-3
Weight Calibration Configuration for Kilograms
2. Press the Scale Zero button with the weights on the platter.
3. Calibration continues with Step 5 - Calibration Success or Failure on page 4-7. Calibration was either
successful or failed at this step.