HOST INTERFACES AND CABLE PINOUTS 2 - 13
Price Computational Scale Interface Circuit Drawing
Price Computational Scale Interface available on AUX 1. (Also see Third Party Scale on page 2-37.)
Figure 2-3
Price Computational Scale Interface
Table 2-3
Auxiliary Connections
Configuration Choices
for the Devices Below
RS-232
Device Port
Configuration
Value
(see parameter
1246
page 2-32
)
Connect Device to These Ports
AUX 1 AUX 2 USB2 USB3
RS-232 auxiliary
scanner, and a
Sensormatic Controller
3
0
1
Sensormatic
Controller
RS-232
auxiliary
scanner
3
USB auxiliary
scanner
3
USB auxiliary
scanner
3
RS-232 auxiliary
scanner, and a Dual
Cable Scanner/Scale
3
1 Dual Cable
Scanner/Scale
2
RS-232
auxiliary
scanner
3
USB auxiliary
scanner
3
USB auxiliary
scanner
3
Dual Cable
Scanner/Scale, and a
Sensormatic Controller
3
2 Sensormatic
Controller
Dual Cable
Scanner/Scale
2
USB auxiliary
scanner
3
USB auxiliary
scanner
3
Third-Party-Scale &
Sensormatic-Controller
4 Third-Party-Scale Sensormatic
Controller
USB auxiliary
scanner
3
USB auxiliary
scanner
3
1
Default setting
2
The Dual Cable Scanner/Scale protocol is 'SASI'
3
In all configurations up to one or two additional USB auxiliary scanners can be connected, but the
total RS-232 auxiliary scanners plus USB auxiliary scanners cannot exceed two. An auxiliary scanner
is not counted until it is attached.