Zebra MP6000 Spezifikationen Seite 152

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 210
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 151
4 - 22 MP6000 INTEGRATOR GUIDE
Successfully
entering scale
legal Calibration
Mode
Step 2 - Program
Legal Parameters
and
Step 3 -
Calibration at NO
LOAD
- Scrolls
C00Lb
OR
C00g
depending on units
programmed as
pounds (lb) or
kilograms (kg)
Step 4 - Calibration
at LOAD
- Scrolls
C25Lb
or
C11g
depending on units
programmed as
pounds (lb) or
kilograms (kg)
Step 5 - Calibration
Success or Failure
-
Repeat scrolls of
CALP
then
CALS
Any step - Calibration
Fails - Scrolls fault
code:
u##
No change Five long beep
tones
Off
Step 3 - Calibration at NO
LOAD
Blinks between CAL00 and
then CAL_ _ with correct
unit icon illuminated (lb or
kg).
Step 4 - Calibration at
LOAD
Blinks CAL25 with lb icon
illuminated, or blinks
CAL11 with kg icon
illuminated.
Step 5 - Calibration
Success or Failure
Blinks between CAL P
(PASS) and CAL S (save
legal parameter settings).
Any step - Calibration fails
blinks CAL F.
Between
calibration steps
No change No change No change Off Blinks HOLD while taking
a measurement.
No platter
installed at
Step
3 - Calibration at
NO LOAD
No change No change Persistent short
beep tone at
1Hz
No change Blinks PLA
Stepping
through a
calibration step
No change No change Single long
beep tone after
pressing the
Scale Zero
button
Off No change
Failure to place
the correct load
on the scale at
Step 4 -
Calibration at
LOAD
C25Lb
or
C11g
depending on units
programmed
No change Two long beep
tones
No change No change
Table 4-6
LEDs, and Beeper Sequences (Continued)
Scale State
7-segment
Diagnostic Display
LED
(System)
Beeper
Sequence
Scale
Zero
Button
(LED)
Optional Scale Display
Seitenansicht 151