4. Ensure that the hinge pin is behind the Bar Sense Cable.
5. Peel the backing off the bar sensor cable and adhere it in the groove on the
bottom of the Printer Frame.
6. Install the Printer Frame in the Lower Housing, again referring to procedure for
RK17393-007 if necessary. Avoid putting excess strain on the remaining cables
connected to the CPU Board.
7. Plug the Bar Sensor Cable into J2 (PAPER) on the CPU Board and lock the
connector.
8. Re-install or, if necessary, replace the Platen and Gear Assembly (refer to the
procedure for AK17393-002)
9. Install the Upper Housing, ensuring that you have re-inserted the LCD and
Keypad ex circuits. Also ensure you have re-installed the D-Rings between
the Upper and Lower Housings.
10. Reinstall the battery
11. Calibrate the Sensors.
Thecalibrationprocedurecanonlybeperformedbycertiedpersonnelusing
special equipment and software.
Using the gray and white swatches, follow the on-screen instructions on
the unit test and set-up software to properly calibrate the sensors. It is
recommended that the complete unit test procedure be performed whenever a
sensor assembly has been replaced.
Peel the adhesive
backing off the Sensor
cable and apply the
Bar Sense Cable into
the groove in the bottom
of the Printer Frame.