• 2-39 • RMAN-RWS-001 rev. B • RW Series Repair Procedures
4. Plug the Keypad ex circuit from the Keypad and Housing into J7 on the CPU
board. Plug the LCD ex circuit from the Keypad and Housing into J6 on the
CPU board. Ensure both connector’s locking tabs are secured.
5. Rotate the Keypad and Housing assembly onto the lower housing of the printer.
Ensure that you tuck the LCD and Keypad Flex circuits behind the edge of the CPU
Board before securing the two housings.
Align the two housings and press the Keypad and Housing rmly into place.
Secure the housings together with the (6) screws you retained when removing
the old Keypad and Housing.
6. Re-assemble either the “D” rings or the carrying strap between the upper and
lower housings before securing the two housings with the long screws. Refer
to the procedure for RK17393-023 for more details.
7. If appropriate, you may install the Product ID label supplied with the kit in the
recess on the top of the new Keypad and Housing.
continued on next page