RMAN-RWS-001 rev. B • RW Series Repair Procedures • 2-92 •
3. Plug the antenna lead into the Radio PCB Assembly, and re-secure it with (2)
screws.
Re-install the Keypad and Housing
1. If necessary, plug the keypad and LCD ex cables into J7 and J9 on the CPU
board.
2. Rotate the Keypad and Housing assembly onto the lower housing of the printer.
Ensure that you tuck the LCD and Keypad Flex circuits behind the edge of the CPU
Board before securing the two housings.
Align the two housings and press the Keypad and Housing rmly into place.
Secure the housings together with the (5) screws you retained when removing
the Keypad and Housing.
3. If you removed the “D” rings between the upper and lower housings, re-
assemble them before securing the two housings with the long screws. Refer
to the procedure for RK17393-023 for more details.
Radio PCB Assembly
J7
J9