Zebra Z6M Spezifikationen Seite 101

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 168
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 100
77259L Rev. 4 12/16/03 Z4M/Z6M Maintenance Manual Page 4-41
3UHYHQWLYHDQG&RUUHFWLYH0DLQWHQDQFH 6HFWLRQ
Figure 4-32. Dancer Assembly
,QVWDOOLQJWKH'DQFHU$VVHPEO\
1. Install the new torsion spring, the first bearing, the dancer, the second bearing, and
then the e-ring.
2. Place the dancer assembly torsion spring back to its operating position against the
printer post and dancer tab. Check to make sure there is tension on the dancer
assembly.
3. Reload the media and ribbon. Close the media door and reconnect power to the
printer.
4. Turn the printer On (l) and print a configuration label.
5LEERQ+HDG2SHQ6HQVRU5HSODFHPHQW
5HPRYLQJWKH5LEERQ+HDG2SHQ6HQVRU$VVHPEO\
1. Turn the printer Off (O) and disconnect the AC power cord.
2. Open the media door and remove media and ribbon from the printer.
E-Ring
Bearing
Dancer
Torsion
Spring
Caution • This installation must be performed by a qualified service technician.
Seitenansicht 100
1 2 ... 96 97 98 99 100 101 102 103 104 105 106 ... 167 168

Kommentare zu diesen Handbüchern

Keine Kommentare