77259L Rev. 4 12/16/03 Z4M/Z6M Maintenance Manual Page 4-23
3UHYHQWLYHDQG&RUUHFWLYH0DLQWHQDQFH 6HFWLRQ
Figure 4-17. Latch Kit Parts
7. Using a small punch, very lightly tap the spring pin from the rear of the platen
housing until it is free from the latch and can be removed.
8. Remove the latch and compression spring.
,QVWDOO/DWFK.LW
1. Refer to Figure 4-17. Install the compression spring on platen housing post.
2. Align latch with spring pin holes. Insert the spring pin through the front hole of the
latch and though the platen housing. The rear hole in the latch is the only small one
and you will need to tap on the spring pin. Lightly tap the spring pin into the rear
hole. Leave equal amounts of spring pin sticking out on each side of latch.
3. Install the strike plate partially into print mechanism by sliding the short side to the
inside of print mechanism as seen in Figure 4-18.
Strike Plate
Cap
Strike
Plate
Strike Plate
Mounting
Screws
Latch Cover
Latch
Spring
Spring
Pin
Adjustment
Screw
Print
Mechanism
Platen
Housing
Ribbon Guide
Plate
Front Edge
Front Edge
Washer
Note • The spring pin must be tapped out from the rear and removed from the
front of the platen housing. Trying to remove the pin in the other direction will
damage the platen housing.