77259L Rev. 4 12/16/03 Z4M/Z6M Maintenance Manual Page 4-43
3UHYHQWLYHDQG&RUUHFWLYH0DLQWHQDQFH 6HFWLRQ
,QVWDOOLQJWKH5LEERQ+HDG2SHQ6HQVRU$VVHPEO\
1. Refer to Figure 4-33. Feed the sensor cable through the opening in the main frame.
Attach the sensor to the main frame with the screw previously removed. Do not
tighten the mounting screw until the sensor gap is established.
Figure 4-34. Ribbon/Head Open Connection to Main Logic Board
2. Refer to Figure 4-34. Reconnect the ribbon/head open sensor connector to the main
logic board (P4). Install new tie wraps in the same locations as previously removed.
3. Refer to Figure 4-34. Using a 0.060 inch (1.5 mm) feeler gauge, check the distance
between the ribbon/head open sensor assembly and the printhead mechanism
assembly when closed. Once this distance is achieved, tighten the mounting screw.
4. Install the electronics cover. Reinstall media and ribbon back into the printer. Close
the media door and reconnect power to the printer.
5. Turn the printer On (l) and unlatch the printhead mechanism. Look at the front panel
to ensure the error LED flashes. Close and latch the printhead mechanism and print
a configuration label using the Cancel Key Self Test to ensure the sensor and printer
work properly.
Main Logic
Board Assembly
Ribbon/Head Open
Sensor Connector
Main Logic
Board Connector
(P4)
Kommentare zu diesen Handbüchern