Page 2-22 Z4M/Z6M Maintenance Manual 77259L Rev. 4 12/16/03
6HFWLRQ 2SHUDWLRQV2YHUYLHZ
$OLJQ6HQVRUV
7UDQVPLVVLYH6HQVRU
There is no positioning of the transmissive sensor. All media is to be loaded through the
transmissive sensor as described in the media and ribbon loading chapters.
6HOHFWLQJWKH0HGLD6HQVRU
A Z4M/Z6M printer can be configured to select either of the sensors. By default the printer
is set to AUTO SELECT during auto-calibration.
The SENSOR SELECT setting may also be changed via ZPL II
®
. The format for the ^JS
instruction is as follows:
^JSx
Where
^JS=Sensor Select
x=Type of sensor
A=Auto Select
R=Reflective Sensor
T=Transmissive Sensor
The sensor can be selected from the LCD menu (see User’s Guide).
Note • Placing an empty 3” core on the hanger will assist the media movement.
Note • The transmissive sensor should not be used when the sensor type is
set to MARK. If the transmissive sensor is the active sensor when the sensor
type is changed from WEB to MARK, an auto-calibration is initiated to make the
reflective sensor active.
The transmissive sensor should not be used when the media type is set to
Continuous. If the transmissive sensor is the active sensor when the media
type is changed from Noncontinuous to Continuous, and auto-calibration is
initiated to make the reflective sensor active.
Note • Changing the SENSOR SELECT setting via the front panel will initiate
an auto-calibration.
Note • Changing the SENSOR SELECT setting via ZPL II will initiate an
auto-calibration.